PEMODELAN SISTEM PENDINGINAN SUNGKUP SECARA PASIF MENGGUNAKAN RELAP5

Andi Sofrany Ekariansyah, ASE and Susyadi, SY and Surip Widodo, SW (2012) PEMODELAN SISTEM PENDINGINAN SUNGKUP SECARA PASIF MENGGUNAKAN RELAP5. PEMODELAN SISTEM PENDINGINAN SUNGKUP SECARA PASIF MENGGUNAKAN RELAP5, 14 (3). pp. 137-145. ISSN 2527-9963

Full text not available from this repository.

Abstract

Semua reaktor daya maju (Generasi III+) memanfaatkan sistem pasif untuk membuang panas melalui sirkulasi alam. Salah satu fitur unik dari reaktor daya maju tipe PWR AP1000 adalah adanya sistem pendinginan sungkup secara pasif (Passive Containment Cooling System / PCS) yang didesain menjaga tekanan sungkup di bawah desain selama 72 jam tanpa tindakan operator. Selama kecelakaan dasar desain seperti kecelakaan hilangnya pendingin atau kecelakaan putusnya jalur uap, terjadi lepasan uap yang bersentuhan dengan dinding baja bejana sungkup yang lebih dingin. Perpindahan kalor dari lepasan uap melalui konveksi dan konduksi dinding baja bejana sungkup akan mengakibatkan perubahan densitas udara akibat pemanasan yang memicu aliran sirkulasi alam dari udara yang akan naik ke atas. Makalah ini bertujuan untuk memperoleh model sungkup AP1000 untuk menunjukkan fungsi PCS menggunakan RELAP5. Fungsi dasar PCS yang ingin diperoleh adalah fenomena perpindahan panas dari uap ke dinding bejana sungkup dan ke udara luar untuk menghasilkan aliran konveksi alam udara. Metodologi yang digunakan adalah pengumpulan data desain, nodalisasi dengan RELAP5, dan simulasi fungsi sungkup berdasarkan masukan kecelakaan dasar desain tertentu. Hasil pemodelan sungkup telah dapat menunjukkan fenomena perpindahan panas dari dalam sungkup ke udara luar dalam bentuk proses kondensasi dan konveksi alam. Hasil perhitungan RELAP5 terhadap model sungkup menunjukkan peningkatan tekanan sungkup yang melebihi tekanan desain sungkup sebesar 59 psig seperti dibandingkan dalam dokumen desain AP1000. Hal itu disebabkan belum dimodelkannya pendinginan sungkup melalui pembasahan tangki sungkup bagian luar dari tangki Passive Containment Cooling Storage Tank (PCCWST). Hasil pemodelan akan digunakan untuk analisis kecelakaan AP1000 secara menyeluruh yang melibatkan fungsi PCS.

Kata kunci: pemodelan, sungkup, AP1000, pasif

All advanced power reactors (Generation III+) utilize passive system to transfer heat by natural convection. One of the unique features of advanced power reactor of AP1000 is the presence of passive containment cooling system (PCS) designed to maintain containment pressure below its design pressure for 72 hours without operator intervention. During a design bases accident, such as loss of coolant accident or main steam line break, steam is released into the containment atmosphere and in contact with cooler steel containment vessel. Heat transfer from steam by convection of steam and conduction of steel wall will initiate air heating in the outside space of containment vessel and initiate natural convection of air from the bottom of air baffle due to the change in the air density. This paper is objected to get a containment model of AP1000 for showing the PCS function using RELAP5. Basic function to be focused is heat transfer phenomena from the steam to the wall containment and to the outside air to obtain natural convection of air. The methodology utilized are collecting design data, containment nodalization using RELAP5, and simulation of containment function based on certain design bases event condition. The results of simulation have shown the heat transfer phenomena from inside containment into the outside air by steam condensation and natural convection of the air. RELAP5 calculation of containment model shows an increase in containment pressure above the containment design pressure of 59 psig as compared in the AP1000 design document. That is because the recent RELAP5 modelling did not include the additional cooling of external surface of containment vessel from the the Passive Containment Cooling Water Storage Tank (PCCWST). The result of modeling will be used for further accident analyses of AP1000 involving the PCS function.

Keywords: modeling, containment, AP1000, passive

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 28 Jun 2018 01:33
Last Modified: 31 May 2022 09:21
URI: https://karya.brin.go.id/id/eprint/3079

Actions (login required)

View Item
View Item